Publication | Peer reviewed papers | Thermische Vergasung und Gasreinigung

Experimental parametric study in industrial-scale dual fluid bed gasification of woody biomass: Influences on product gas and tar composition

Kuba M, Hofbauer H

Published 2018

Citation: Kuba M, Hofbauer H. Experimental parametric study in industrial-scale dual fluid bed gasification of woody biomass: Influences on product gas and tar composition. Biomass and Bioenergy. 2018, 115: 35-44.

Abstract

Tar measurements at two industrial-scale DFB gasification plants showed clear trends regarding the influence of the above mentioned parameters on the product gas and tar composition. Since data was gathered during tar measurement campaigns over the course of four years the density of information in industrial-scale was increased significantly. As different operation points, e.g. different capacities of the power plant, are included in the consideration, the verisimilitude is comparably high.

It was shown, that reducing the operation temperature leads to an increase of the total tar amounts. However, while the concentration of the tar compounds benzofuran, styrene, and 1H-indene was increased when lowering the temperature, the concentration of naphthalene was decreased. These results were in good correlation with previous work from lab-scale investigations. The temperature did not have a measureable influence on the concentration of the tar compounds anthracene and ace-naphthalene, which was against former experience from lab-scale. The concentration of those larger PAHs anthracene and ace-naphthalene was more dominantly influenced by the bed height in the gasification reactor. Increasing the bed height led to a decrease of the concentration of larger PAHs while it did not have a distinctive influence on benzofuran, styrene, and 1H-indene.

The reactor design was identified as an influencing effect, due to the presence of a moving bed section above the inclined wall, where no fluidization is ensured. Thus, additional fluidization nozzles were installed to reduce the effect of the inclined wall. Finally, two operation points for optimized long-term operation were derived from the results.